RealStar® Malaria PCR kits
The RealStar® Malaria PCR Kit 1.0 is an in vitro diagnostic test, based on real-time PCR technology, for the detection of Plasmodium spp. specific DNA, including the five human pathogenic species Plasmodium falciparum, Plasmodium vivax, Plasmodium malariae, Plasmodium ovale and Plasmodium knowlesi.
The RealStar® Malaria Screen & Type PCR Kit 1.0 is an in vitro diagnostic test, based on real-time PCR technology, for the detection and differentiation of DNA of the Plasmodium species Plasmodium malariae, Plasmodium ovale, Plasmodium knowlesi, Plasmodium vivax and Plasmodium falciparum.
To see the product specific key features of this kit please click here.
RealStar® Malaria PCR Kit 1.0


RealStar® Malaria PCR Kit 1.0 The RealStar® Malaria PCR Kit 1.0 consists of two master reagents (Master A and Master B), Internal Control (IC), Positive Control, PCR grade water.
Products not licensed with Health Canada and not FDA cleared or approved. Kits not available in all countries.
Key features
- Detection of Plasmodium spp. specific DNA
- Detection of all five currently known human pathogen Plasmodium species (P. falciparum, P. vivax, P. ovale, P. malariae and P. knowlesi)
- Ready-to-use kit including Internal Control and Positive Control
- Compatible with various real-time PCR platforms
- CE-IVD marked in vitro diagnostic test

RealStar® Malaria PCR Kit 1.0
Order No. | 341013 |
Rxns | 96 |
Transportation | Dry ice |
For use with | Mx 3005PTM QPCR System VERSANT® kPCR Molecular System AD ABI Prism® 7500 SDS and 7500 Fast SDS LightCycler® 480 Instrument II Rotor-Gene® 6000 Rotor-Gene® Q 5/6 plex Platfom CFX96™ Real-Time PCR Detection System |
RealStar® Malaria Screen & Type PCR Kit 1.0


RealStar® Malaria S&T PCR Kit 1.0 The RealStar® Malaria S&T PCR Kit 1.0 consists of two different PCR assays with 48 reactions, each four master reagents (Master A and Master B targets Pk/Pm/P and Master A and Master B targets Pf/Pv), Internal Control (IC), Positive Control Mix 1 [P. ovale, P. malariae, P. knowlesi], Positive Control Mix 2 [P. vivax, P. falciparum], PCR grade water.
Products not FDA cleared or approved. Kits not available in all countries.
Key features
- Detection and differentiation of DNA of the Plasmodium species Plasmodium malariae, Plasmodium ovale, Plasmodium knowlesi, Plasmodium vivax, and Plasmodium falciparum
- Ready-to-use kit including Internal Control and Positive Control
- Compatible with various real-time PCR platforms
- CE-IVD marked in vitro diagnostic test
RealStar® Malaria Screen & Type PCR Kit 1.0
Order No. | 351013 |
Rxns | 2 x 48 |
Transportation | Dry ice |
For use with | Mx 3005PTM QPCR System VERSANT® kPCR Molecular System AD ABI Prism® 7500 SDS and 7500 Fast SDS LightCycler® 480 Instrument II Rotor-Gene® 6000 Rotor-Gene® Q 5/6 plex Platfom CFX96™ Real-Time PCR Detection System CFX96™ Deep Well Real-Time PCR Detection System |
RealStar® Malaria PCR Kit 1.0
Release date: | 08/2018 |
Date de sortie: | 08/2018 |
Fecha de lanzamiento: | 01/2017 |
Data de lançamento: | 08/2018 |
Data di rilascio: | 08/2018 |
RealStar® Malaria Screen & Type PCR Kit 1.0
Release date: | 03/2022 |
Date de sortie: | 03/2022 |
Fecha de lanzamiento: | 03/2022 |
Data de lançamento: | 03/2022 |
Data di rilascio: | 03/2022 |
References RealStar® Malaria PCR kits
Validation of a new real-time PCR based kit for detection and typing of 5 human pathogenic Plasmodium species, including P. knowlesi in whole blood specimen
pdfPoster: | IMED 2018 |
Use of Capillary Blood Samples Leads to Higher Parasitemia Estimates and Higher Diagnostic Sensitivity of Microscopic and Molecular Diagnostics of Malaria Than Venous Blood Samples
pdfJournal of Infectious Diseases: | 2018;218:1296–305 |
Downloaded from: | https://academic.oup.com/jid/article-abstract/218/8/1296/5003449 |
A real-time PCR based Malaria-typing assay for the detection and differentiation of all five human pathogenic Plasmodium species
pdfPoster: | KIT Köln 2014 |
Analytic and diagnostic evaluation of a real-time PCR based Malaria-screening assay
pdfPoster: | EMMD Scheveningen 2013 |
RealStar® Malaria PCR Kit 1.0
Konformitätserklärung/Declaration of Conformity (DoC)/Déclaration de conformité RealStar® Malaria PCR Kit 1.0 (DE, EN, FR)
pdfVeröffentlichungsdatum/Release date/Date de sortie: | 17.05.2022 |
Declaración de conformidad/Dichiarazione di Conformità/Declaração de conformidade RealStar® Malaria PCR Kit 1.0 (ES, IT, PT)
pdfFecha de lanzamiento/Data di rilascio/Data de lançamento: | 17.05.2022 |
RealStar® Malaria Screen & Type PCR Kit 1.0
Konformitätserklärung/Declaration of Conformity (DoC)/Déclaration de conformité RealStar® Malaria Screen & Type PCR Kit 1.0 (DE, EN, FR)
pdfVeröffentlichungsdatum/Release date/Date de sortie: | 17.05.2022 |
Declaración de conformidad/Dichiarazione di Conformità/Declaração de conformidade RealStar® Malaria Screen & Type PCR Kit 1.0 (ES, IT, PT)
pdfFecha de lanzamiento/Data di rilascio/Data de lançamento: | 17.05.2022 |